Toxic Residues and Unsuspecting Clients: Developing a Test Kit for Identifying Illicit Laboratory Wastes
ISEF · 2017 Chemistry
Overview
The goal of this project was to create a relatively inexpensive test kit which identified the previous existence of a methamphetamine laboratory by detecting lithium carbonate residues. Due to lithium carbonate’s LD50, it should be identified to at least 2.04M and preferably past 5.37x10-1M. During Experiment I a lithium carbonate dilution series was created, and each concentration was burned. A spectrometer was used to read the intensity of the red emitted by the flame. The experiment was stopped after 1x10-4M lithium carbonate was burned since no red flame was observed. Another lithium carbonate dilution series was created during Experiment II, and each solution was poured on a glass surface. Distilled water was used as a negative control. Once the solutions had evaporated and left behind a residue, different solvents, which included 5% acetic acid, 5% hydrochloric acid, and distilled water, were used to soak up the residues onto filter paper. The filter paper was burned, and observations from the naked eye and through a red glass filter were recorded. The experiment was stopped after 1x10-5M lithium carbonate was burned since no red flame was observed after the 1x10-2M solution. Both experiments identified lithium carbonate past 5.37x10-1M, although Experiment I was more successful due to the filter paper’s combustion hiding the red flame in Experiment II. Differing solvents and observation techniques had no effect on the flame test. Sources of error included parallax error, inoculating loop contamination, and differing times of exposure between the saturated filter paper and lithium carbonate residues.
Competition history
- ISEF 2017
Resources
Related projects
ISEF · 2022
So Li?! Designing a Novel Approach for Rapid Lithium Detection: Investigating Enzymatic Coupling to Produce Hydrogen Peroxide for the Development of Colorimetric and Fluorescent Sensors and Testing the Efficacy of Horseradish Peroxidase, 3,3',5,5' Tetramethylbenzidine, and Amplex Red
ISEF · 2018
Is Your Water Safe to Drink? Development of a Novel Home Test Method to Quantitatively Determine the Concentration of Lead in Water, Phase Two
ISEF · 2014
You Missed a Spot: Accuracy of Luminol Chemiluminescence to Detect Blood at a Crime Scene using Concealment Techniques and Measurements of False Positives
ISEF · 2021
A Study on the Production of Kit to Detect Nickel Ion in Waste Water Using Luminol
Closest projects by meaning, across every fair and year in the corpus.
Source: Regeneron International Science and Engineering Fair