The Use of Background Suppression in MRIs to Increase Signal
CSEF · 2010 Electronics & Electromagnetics Honorable_mention Award
Overview
Objectives/Goals The objective of this project is to increase the efficiency of ASL (Arterial Spin Labeling) perfusion imaging. This is done through the application of Background Suppression (BGS) in MRI to decrease the signal and the excess noise, but overall increase the signal to noise ratio. Methods/Materials First, the volunteer must be informed of the proper safety and given the consent form to sign. Then a localizer scan is performed to get a general image of the brain. After that, the 4 ASL scans are conducted: a control (no BGS), traditional BGS (tag location and up), extended BGS (+100mm area) and global BGS (maximum area). The raw data from the scans must be extracted and then converted to number/picture form through a Matlab code. Lastly, the Signal to Noise ratios of each scan are compared to find which produces the greatest ratio to make a conclusion. Results Format = experiment: signal/noise/ratio Trial 1: Control: 34.7345/22.3955/1.5063 : 1, Trad. BGS: 26.7062/12.6313/2.1143 : 1 Ext. BGS: 23.9428/8.5707/2.7936 : 1, Global BGS: 33.0131/7.2024/4.5836 : 1 Trial 2: Control: 29.4384/22.3672/1.3161 : 1, Trad. BGS: 23.6377/10.5630/2.2378 :1 Ext. BGS: 21.8008/8.3783/2.6021 : 1, Global BGS: 28.7263/5.8229/4.9333 : 1 Trial 3: Control: 29.4355/15.3740/1.9146 : 1, Trad. BGS: 21.2455/9.2045/2.3082 : 1 Ext. BGS: 19.3661/10.8103/1.7914 : 1, Global BGS: 33.2441/5.3993/6.157 : 1 Conclusions/Discussion The 3 trials unanimously showed that BGS did increase the signal to noise ratio. The general trend found was that the greater the area covered by BGS, the higher the signal to noise ratio. Thus, global BGS was the best option. This finding is beneficial to the world of medicine in that currently, doctors use the traditional BGS, but if they switched to global BGS, the ratio would increase 4 to 6 fold. Thus, that create higher quality images purely from signal. The global BGS is easy to use: it can be activated with a click of a button.
Summary statement
The use of background suppression to increase the signal to noise ratio in ASL scanning so that images are more efficient and better quality.
Help received
Used MRI equipment at UCSD under the supervision of Dr.Eric Wong and his student Guo Jia
Awards (1)
- Honorable Mention
Competition history
- CSEF 2010
Resources
Related projects
ISEF · 2021
Improving Image Contrast in MRI 7T for Early Diagnosis and Disease Detection
ISEF · 2014
Computational Simulation of T1 Contrast in BOLD-fMRI Scans to Improve Analysis Potential
JSHS · 2023
Novel Imaging Approaches for the Quantification of Changes in Perivascular Space Volume and Morphology in Response to Transcranial Direct Current Stimulation
ISEF · 2019
Fast MRI: Reconstructing MR Images Using Undersampled k-space and a GAN
CSEF · 2010
Developing a Low Cost Method of Detecting Nuclear Magnetic Resonance
ISEF · 2023
Optimal Acquisition and Processing Strategies for Accurate and Precise Neurite Orientation Dispersion and Density Imaging (NODDI) Modeling of the Spinal Cord
ISEF · 2026
Developing a Novel Adaptive Tuning Module for Real-Time Frequency Correction in Radiofrequency Coils During Concurrent TMS-fMRI
JSHS · 2024
High-Resolution Super sampling of BASP-ORCA Contrast Agents in Magnetic Resonance Imaging
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: California Science & Engineering Fair public projects