Overview
Objectives/Goals Will the replacement of stiff cross-members by viscous dampers decrease the amount of acceleration that a building undergoes during an earthquake? My objective is to test two model buildings, one with stiff cross-members, and one with viscous dampers to determine the amount of acceleration that they are subjected to. Methods/Materials Materials: Wood of various sizes; balsa wood; MDF board; AC motor; drill; fax paper; screws; custom made measuring transparency; custom made drill bit Methods: 1) Create shake table and data tower to apply the same amount of shaking to the buildings. 2) Create two identical buildings with three floors. One will have stiff cross members one floor one, while the other will have viscous dampers on floor one. 3) Attach building to shake table and set the paper in place. 4) Turn on the shake table and the paper roller for exactly five seconds, then turn off. 5) Repeat procedure number four 200 times (100 per building). 6)Measure the period with the highest total displacement and count the number of periods. 7) Record data and use it for the necessary calculations. Results The building with the viscous damper had a much lower acceleration and displacement(1.10mm/s; 5.77mm) than the building with the stiff cross-member(1.29mm/s; 8.9mm). The calculations and results also proved to be extremely accurate with a standard deviation of 0.086. These results prove how well viscous dampers help to dissipate the effects of the seismic energy on a building's response during an earthquake. Conclusions/Discussion Viscous dampers substantially help to reduce the mount of displacement and acceleration that a building undergoes during an earthquake. By reducing the amount of displacement and acceleration, the building will have less stress on its structure and therefore is less likely to collapse.
Summary statement
I tested viscous dampers vs. stiff cross members to measure the reduction of the amount of acceleration that a building undergoes during an earthquake.
Help received
Mother helped for ideas on backboard display; Brother helped soulder wires; Father helped give tips on building the apparatus.
Competition history
- CSEF 2006
Resources
Related projects
CSEF · 2010
Friction Dampers: Putting the Brakes on Earthquakes
CSEF · 2011
What's Shakin'? A Study on Finding the Most Earthquake-Resistant Design of Base Isolation During Seismic Activity
CSEF · 2019
The Effect of Tuned Mass Dampers on Oscillating Buildings
CSEF · 2019
Shake It Off
CSEF · 2011
Efficacy of Seismic Retrofits in Diminishing Surface Wave Induced Swaying
CSEF · 2009
Building Buildings Better. Which Design Does Better in an Earthquake: Tuned Mass Damper or Base Isolator?
CSEF · 2013
Seismic Vibration Control: Finding the Best Strategy for Minimizing Damage to a Structure During an Earthquake
CSEF · 2019
Minimizing Earthquake Damage for Buildings
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: California Science & Engineering Fair public projects