Chloramine Test Kits for an Efficient Process of Swimming Pools' Disinfection
ISEF · 2019 Chemistry Fourth Award
Overview
Chloramine in swimming pools is considered hazardous. It is generated by reaction of free chlorine with amine compounds including urine and perspiration. To eliminate chloramine, excessive amount of hypochlorite compounds is normally added to swimming pools in a method called “pool shocking”. However, with this method, the pool needs 6-8 hours of resting to allow the chlorine concentration to drop below 3 ppm before swimmers re-entering the pool. This project develops a direct chloramine test kit utilized for efficient pool treatment. The test kit contains two main parts: (a) salicylate reagent, used to react with chloramine to normalize the measurement, and (b) sodium iodide and starch mixture, used to react with chloramines as a colorimetric indicator for measuring chloramine concentration. Before chlorine treatment, water from the pool usually contains excessive chloramine and little chlorine, resulting in reaction product (triiodide/starch complex) having blue color and indicating that the sample is not yet at the chlorination breakpoint. Then, calcium hypochlorite is gradually added until the solution turned colorless to find the chlorination breakpoint, which is the lowest chloramine concentration. Appropriate amount of chlorine for pool treatment can then be calculated. The finding indicates the convenience and effectiveness of the developed test kit, allowing less use of hypochlorite compounds and less waiting time for swimmers. To enhance the ability of the test kit, a color sensor on a microcontroller board is applied to distinguish more color levels of the solution and then the program automatically calculates the proper amount of chlorine for pool treatment.
Awards (1)
- Fourth Award of $500 $500
Competition history
- ISEF 2019
Resources
Related projects
ISEF · 2019
Engineering an Automated Chloramine Testing Device
CSEF · 2026
Chlorine Neutralizing Shampoo
ISEF · 2026
Scalable Environmental Proxy Sensing Framework for Real-Time Detection and Risk Characterization of Chloramine Accumulation in Indoor Aquatic Systems
CSEF · 2007
Chlorine vs. Saline Water Systems: Pool Water Quality
ISEF · 2014
Optimal Chlorine/Ammonia Chloramine Equilibrium Ratios to Prevent Lead Leaching
CSEF · 2014
Effects of Sodium Hypochlorite and Chloramine on Pimephales promelas and Escherichia coli
ISEF · 2021
Remote Monitoring System for Swimming Pools Water Quality (IOT)
CSEF · 2018
Comparison of Oxidizers in the Removal of NDMA in the UV Advanced Oxidation Process of Treating Drinking Water
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: Regeneron International Science and Engineering Fair