SODIS: Solar Water Disinfection
CSEF · 2011 Microbiology (General)
Overview
Objectives/Goals The objective is to test whether or not the opacity of PET bottles affects the solar disinfection of pathogenic-infested water. Methods/Materials Fourteen PET bottles, fourteen petri dishes, nutrient agar, and an Escherichia coli slant culture are prepared in order to begin the experiment. Six of the bottles are scratched to varying opacities of 25%, 50%, and 75%. Four of the bottles are scratched to 100% opacity, and the other four are left unscratched. Approximately 0.25 milliliters of Escherichia coli are pipetted into each bottle. Seven bottles are placed in the sunlight for six hours, and the rest are placed in a box covered with a UV light bar for six hours. A sample of each bottle is spread on separate petri dishes, and then after twenty four hours of incubation, the colonies are counted and observed. Results In the sun trials, there was no growth of bacteria in any of the agar plates. The shade agar plates had varying amounts of bacterial growth that seemed to be slightly affected by opacity. However, in the trial with the UV bar, all agar plates had some degree of growth, and the opacity affected the amount of bacterial growth to a slight degree. Shade was simulated by covering two of the bottles (0% scratched and 100% scratched) with a cloth, thereby creating indirect UV light exposure. Interestingly enough, the bottles with indirect exposure had agar plates where the bacteria appeared in approximately 12 hours, while the bottles with direct UV exposure had agar plates where the bacteria appeared 24 hours later. Conclusions/Discussion The opacity of the bottle did not appear to affect the amount of bacteria neutralized by the sun's rays. The shade agar plates had varying amounts of bacterial growth that seemed to be slightly affected by opacity. However, in the UV bar trial, all agar plates had some degree of growth, and the opacity affected the amount of bacterial growth to a slight degree. The results were not as expected, because the sun was strong enough to deactivate all bacteria, regardless of opacity.
Summary statement
The purpose of this project is to determine if the degree of opacity of PET bottles affects the solar disinfection of pathogenic-infested water.
Help received
Parents helped to acquire materials and supervise the inoculation, observation, and disposal of the Escherichia coli
Competition history
- CSEF 2011
Resources
Related projects
CSEF · 2004
Does the Surface Clarity of Plastic Bottles Affect Solar Water Disinfection as Measured by the Presence of E. coli?
CSEF · 2015
More Water, Please?
CSEF · 2015
Can Water Be Disinfected Using Only Sunlight?
CSEF · 2004
Solar Disinfection of Water
CSEF · 2009
Effect of Increased Light Intensity and Bottle Size on Solar Water Purification
CSEF · 2006
Using Solar Energy to Make Drinking Water Safe
ISEF · 2021
UVClean or SODISgusting: Comparing the Effectiveness and Efficiency of an Ultra-Violet C (UVC) Sanitizer Box and the Solar Water Disinfection (SODIS) Method
ISEF · 2016
Effect of Photocatalysis on SODIS: The Implementation of Titanium Dioxide, Zinc Oxide, and Chitosan in Solar Water Disinfection
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: California Science & Engineering Fair public projects