Increasing Efficiency of Existing Air Conditioners by Only Changing the Timing of Operation
CSEF · 2009 Energy & Power (Junior Division Only)
Overview
Objectives/Goals The purpose of this project was to determine whether it is more efficient to run an air conditioner in the day or night and in long or short time blocks. Methods/Materials More than 200 cycles of a home air conditioning system was analyzed over the period of a month. Eighteen data loggers, some with internal and some with external temperature probes, were placed outside, in the attic, before and after the evaporator and below return and outlet air vents. Relative efficiencies were calculated by comparing average temperature differences between inlet and outlet air vents (delta T) at differing times of day and lengths of air conditioner run. To ensure that the temperature measurement devices responded quicker than the air conditioner transients, a transient test was conducted by comparing the characteristic times of the data loggers against the air conditioners response. Winter data from the heater was used as a complementary data because it used the same duct system and supplemented the summer A/C data in looking at impact of run length. Results The measurement device transient tests on the main data logger type showed a six minute response time to reflect 80% of a 12°C step change. After device modification, the response time was one minute. Typical A/C run lengths were five minutes. On long runs, the delta T dropped from 12°C to 8°C as the attic temperature rose from 25°C to 35°C. On short runs, typical delta T's were as low as 4°C when the attic temperature was ~40°C. As the attic temperature started dropping below ~35°C the temperature differences rose to 6-8°C. Winter heater delta T's were 15°C for long runs and only 5-8°C for short runs. Conclusions/Discussion Daytime vs. nighttime attic temperatures reduce the air conditioner cooling capacity by approximately a third. Long runs show greater cooling capacity but also drop with higher attic temperature; the winter heating analysis is consistent showing twice the heating delta T at longer run times. Heat conduction into the ducts and leakage on the inlet side taking attic air into the ducts both reduce the delta T that cools or heats a house.
Summary statement
Relative efficiencies were calculated by measuring temperatures throughout a house to increase efficiency of the existing air conditioner by only changing the timing of operation.
Help received
Discussions with parents. Dad showed how to run the data loggers and wrote some VBA used to catalogue and retrieve the data quickly.
Competition history
- CSEF 2009
Resources
Related projects
CSEF · 2010
Using the Thermal Mass of a Building to Lighten the Load of an Air Conditioner
CSEF · 2019
Does Limiting Direct Sunlight with Different Types of Shade Materials Make an Air Conditioner Work More Efficiently?
CSEF · 2013
A Novel Method of Improving Home Solar Panel Output: A Fundamental Concept with Profound Implications
CSEF · 2012
A Green Solution to Reducing Cooling Loads on a Building, A Two-Year Project
CSEF · 2010
Using Passive Solar Design to Cool and Heat a House
CSEF · 2010
Sunny Money: Weighing Variables in Solar Water Heating Systems to Improve Cost-Effectiveness
CSEF · 2013
Catching Rays: Analyzing Maximum Solar Efficiency as Related to the Sun's Position throughout the Day
CSEF · 2010
Going Green: An Innovative Approach to Comfort
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: California Science & Engineering Fair public projects