I Beam

CSEF · 2002 Structural Capability & Strength of Materials (Junior Division Only)

Overview

Objectives/Goals To determine whether or not size effected the weight carrying and span capacity of an I-beam. If it did, what variations of the flange / web ratio made it stronger, and what variations made it weaker. Hypothesis: I believe that the size of an I-beam (flange /web ratio) would effect the load carrying and span capacity of an I-beam. After researching, I thought that the higher and thicker the web, and the wider and thicker the flanges, the more weight an I-beam could carry with out deflecting as much. Methods/Materials Using the strips of Pine wood, I first designed and constructed 5 different sized I-Beams labeling them 1-5. I then calculated how many fluid ounces it would take to weigh a pound. I found that it would take 15.4 fl. Oz. to equal a pound. Then, I placed the I-Beam #1 on wood supports, and strapped on the five-gallon bucket using the thin fabric. I placed 15.4 fl. Oz. (1 pound) in the bucket. I placed a 24-inch straight edge across the top of the beam and measured the distance between the bottom of the straight edge and the I-beam with a 200mm ruler to find the amount of deflection. I repeated the process 4 more times and then did the rest of the I-beams in the same manner Results I-beam # 1 deflected 1.5 mm with one pound, 4mm with two pounds, 6mm with 3 pounds, and 9mm with 4 pounds. I-beam # 2 deflected 1.5mm with 4 pounds, 2mm with 5 pounds, 2.5mm with 6 pounds, and 3mm with 7 pounds. I-beam # 3 deflected 1.5mm with 9 pounds, 1.75 mm with 11 pounds, 2mm with 15 pounds, and 2.5 mm with 19 pounds. I-beam #4 deflected 1.5 mm with 7 pounds, 1.75mm with 9 pounds, 2mm with11 pounds, and 3mm with 15 pounds. I-beam #5 deflected .5mm with 4 pounds, 1mm with 7 pounds, 1.5mm with 10 pounds, and 2mm with 13 pounds. Conclusions/Discussion Conclusion: In conclusion, my hypothesis was somewhat right and somewhat wrong. I found that size did affect a beams strength, and that the wider the flanges and taller the web, the stronger the I-beam would be. I also found out that the web height was more important than the flange width and thickness.

Summary statement

THE DIMENSIONS OF AN I- BEAM AFFECTS ITS LOAD CARRYING AND SPANNING CAPACITIES.

Awards (1)

  • Category Award

Competition history

  • CSEF 2002 Structural Capability & Strength of Materials (Junior Division Only) · Entry J1803

Resources

Related projects

Closest projects by meaning, across every fair and year in the corpus.

Browse more like this

Source: California Science & Engineering Fair public projects

Save projects to your library

Sign in with Google to keep track of projects you find interesting, organized into folders. An account also raises your daily allowance for “Has this been done?”, and lets you create a key for the MCP server with a much higher limit than anonymous use. Browsing stays public.

Continue with Google