Developing a Novel Flexible MoS2 Biosensor to Detect Lower-Concentrated Biomolecules at the Femtomolar Level
CSEF · 2017 Chemistry Fourth Award
Overview
Objectives/Goals The object of this study is to develop a novel flexible MoS2 biosensor to detect very lower-concentrated biomolecules. Methods/Materials I successfully fabricate a MoS2 biosensor on polyimide film, a flexible substrate which has great potential applications. The MoS2 biosensors can be used for rapid biomolecule quantification at fM-levels by analyzing the initial slopes of time-dependent response curves. The flexible MoS2 biosensors exhibited a detection limit for biomolecules as low as 50 fM that is about 10,000 times lower concentration than that can be detected by the conventional biosensor like ELISA. Results The fabricated MoS2 biosensors can be used for rapid biomolecule quantification at fM-levels by analyzing the initial slopes of time-dependent response curves. The multiple sensors can be utilized to enable quantification of low-abundance biomarker molecules as well as the affinities and kinetics of antibody-mediated binding events. The flexible MoS2 biosensors exhibited a detection limit as low as 50 fM that is about 10,000 times lower concentration than that can be detected by the conventional ELISA method. Conclusions/Discussion The MoS2 biosensors can be used for rapid biomolecule quantification at fM-levels by analyzing the initial slopes of time-dependent response curves. The multiple sensors can be utilized to enable quantification of low-abundance biomarker molecules as well as the affinities and kinetics of antibody-mediated binding events. The flexible MoS2 biosensors exhibited a detection limit as low as 50 fM that is about 10,000 times lower concentration than that can be detected by the conventional biosensor like ELISA.
Summary statement
I have successfully fabricated a flexible MoS2 biosensor that can detect biomolecules with a concentration as low as 50 fM that is about 10,000 times lower concentration than the conventional ELISA method.
Help received
I have been working on this project for two years at a research laboratory. They trained me on equipment and I had some discussion with them.
Awards (1)
Competition history
- CSEF 2017
Resources
Related projects
ISEF · 2017
Developing a Novel Flexible MoS2 Biosensor to Detect Lower-Concentrated Area of Biological Molecules at the Femtomolar Level
CSEF · 2016
Developing a NanoFET Biosensor Based on MoS2 2D Material for Detecting Low Concentration Illness-Related Molecules
ISEF · 2018
Fabricating a Novel Ultrasensitive Flexible Biosensor with Patterned 10 nm Single Antibody Size Periodic Line Channel Created by Directed Molecular Self-Assembly to Achieve Extremely High Accuracy in the Earlier Detection of Cancer
CSEF · 2015
Novel Self-Reporting Photonic Crystal Nanosensor: Controllable Hydrophobicity, Flexibility, and Chemical Resistance
CSEF · 2017
Carbon-MEMS Suspended Nanogap: Current Amplifying Working Electrode for Biosensor
ISEF · 2017
Nanofabrication and Electroanalysis of Carbon-MEMS: A Suspended Nanometric Gap for Sensitive Biosensing
CSEF · 2017
Application of Nanostructured Porous Silicon as an Electrical Biosensor for Alzheimer's Screening
CSEF · 2017
Characterization of 2D Molybdenum Disulfide Crystal Growth for Nano-Optics and the Extension of Moore's Law
Closest projects by meaning, across every fair and year in the corpus.
Browse more like this
Source: California Science & Engineering Fair public projects