Adjusting Blood Sugar Levels to Address Diabetes

CSEF · 2015 Electronics & Electromagnetics

Overview

Objectives/Goals Diabetes patients face challenges to continuously check and adjust their blood glucose levels. My objective is to create a simplified artificial pancreas model that continuously checks glucose levels, automatically adjusts high glucose levels, and gives warning for low glucose levels. Methods/Materials My model contained two circuits: first to deliver insulin using peristaltic pump and second to warn using LED. I used acid-base chemistry and represented an acidic solution (vinegar) for high blood glucose levels, a neutral solution for normal glucose levels, and a basic solution (sodium bicarbonate) for insulin. I made a conductivity sensor that uses idea of electrolysis to represent the glucose sensor. As the conductivity sensor has low enough resistivity in acidic solutions, enough current goes into the transistor and pump runs delivering basic solution until the acidic solution becomes neutral. In the second circuit, I used a NOT gate to reverse the effects. LED turns on when the solution becomes neutral indicating acceptable glucose levels and off in basic solution showing low glucose. I tested the response of pump and LED. I measured original and attained pH of the solution and how much basic solution was used to neutralize. Results Pump started automatically in acidic solutions (high glucose) of pH 2.5, 4, and 5, and on average, stops at pH 6.28. On average, pump delivered 190 mL basic solution to neutralize 200 mL acidic solution (pH 2.5), 114 mL basic solution to neutralize 220 mL acidic solution (pH 4), and 139 mL basic solution to neutralize 270 mL acidic solution (pH 5). Pump did not deliver the exact same amounts of basic solution for the same pH of acidic solution, however, the variation is acceptable as pH is the negative logarithm of molarity of hydrogen ions in a solution. Pump did not start to deliver basic solution into neutral (normal glucose) of pH 6.5. LED turned on in neutral solutions. LED turned off in basic solutions. Conclusions/Discussion My system is able to automatically deliver basic solution, neutralizing the acidic solution. This represents delivering insulin to reduce glucose levels to an acceptable range. It does not deliver basic solution to neutral solutions (normal glucose). It gives warning in basic solutions (low glucose) through LED indicating patients need food. I will explore ways to convert my prototype into a practical, compact artificial pancreas.

Summary statement

I created a model of an artificial pancreas that continuously checks blood sugar levels, automatically normalizes high glucose levels, and gives warning for low glucose levels.

Help received

Father taught how to troubleshoot circuits and other difficult-to-understand concepts; Mother supervised me during my experiments.

Competition history

  • CSEF 2015 Electronics & Electromagnetics · Entry J0913

Resources

Related projects

Closest projects by meaning, across every fair and year in the corpus.

Browse more like this

Source: California Science & Engineering Fair public projects

Save projects to your library

Sign in with Google to keep track of projects you find interesting, organized into folders. An account also raises your daily allowance for “Has this been done?”, and lets you create a key for the MCP server with a much higher limit than anonymous use. Browsing stays public.

Continue with Google