A Weir-d Project

CSEF · 2006 Aerodynamics/ Hydrodynamics

Overview

Objectives/Goals The purpose of my project was to confirm that the weir equation that relates water height or stage above an obstruction to stream flow in a rectangular stream channel is adequate. Furthermore, I wanted to find out just how accurate the weir coefficient of 0.465 is. Methods/Materials A stream model was constructed. To find the amount of discharge for different undetermined flow settings on my pump, I operated eight runs in which I measured the volume of water coming from the stream and divided it by the amount of time it took. I then substituted values in the weir equation for each of the eight runs I did to find the discharge according to that equation. The different flow measurements of the model and the equation were compared. I then back calculated my results for each run to find what the coefficient would be if my results were without error. Results The difference between the calculated discharge using the timed bucket method and using the weir equation ranged from 0.3 # 25.6 cubic centimeters per second. The timed bucket flows ranged from 114.4 # 376.1 and the calculated discharges of the equation ranged from 114.1 # 351.5. Furthermore the relationship between the weir equation and the timed bucket almost fit a one to one relationship with regression analysis giving an equation of y = 0.9533x with an r squared of 0.9986. If the calculated discharges of the model were exact, the coefficient would range from 0.466 # 0.497, but, as I said, my calculated model discharges were slightly off. Conclusions/Discussion My results show that this weir equation is a sufficient representation of the discharge of a stream and the weir coefficient 0.465 is accurate. Because I was unable to take absolutely precise measurements of the water in each of the runs, the calculated discharge of the model was slightly different than that of the equation and the weir coefficient altered somewhat when I back calculated. However, it was an insubstantial variation and it is obvious that the weir equation can be relied on to take accurate flow measurements and the weir coefficient of 0.465 is adequate.

Summary statement

In my project, I tested a weir equation for its accuracy measuring stream flow.

Help received

My dad helped me learn the statistics; My mom helped me build the model.

Competition history

  • CSEF 2006 Aerodynamics/ Hydrodynamics · Entry J0123

Resources

Related projects

Closest projects by meaning, across every fair and year in the corpus.

Browse more like this

Source: California Science & Engineering Fair public projects

Save projects to your library

Sign in with Google to keep track of projects you find interesting, organized into folders. An account also raises your daily allowance for “Has this been done?”, and lets you create a key for the MCP server with a much higher limit than anonymous use. Browsing stays public.

Continue with Google